Baxter

20 CVEs across 38 Baxter products. Browse Baxter vulnerabilities, severities, and proof-of-concept exploits.

Baxter products with known CVEs

ProductCVEs
Sigma Spectrum Infusion System10
Sigma Spectrum Infusion System Firmware10
Life2000 Ventilation System8
Wireless Battery Module8
Em12006
Em1200 Firmware6
Em24006
Em2400 Firmware6
Baxter Spectrum Iq 35700bax34
Baxter Spectrum Iq 35700bax3 Firmware4
Baxter Spectrum Wireless Battery Module (Wbm)4
Sigma Spectrum 35700bax4
Sigma Spectrum 35700bax24
Sigma Spectrum 35700bax2 Firmware4
Sigma Spectrum 35700bax Firmware4
Sigma Spectrum Infusion System4
Spectrum Wireless Battery Module4
Spectrum Wireless Battery Module Firmware4
Prismaflex3
Prismaflex Firmware3
Prismax3
Prismax Firmware3
Connex Health Portal2
Connex Health Portal2
Phoenix X361
Phoenix X36 Firmware1
Welch Allyn Configuration Tool1
Welch Allyn Connex Cardio1
Welch Allyn Connex Spot Monitor1
Welch Allyn Diagnostic Cardiology Suite1
Welch Allyn Hscribe Holter Analysis System1
Welch Allyn Hscribe Holter Analysis System Firmware1
Welch Allyn Q-Stress Cardiac Stress Testing System1
Welch Allyn Q-Stress Cardiac Stress Testing System Firmware1
Welch Allyn Rscribe Resting Ecg System1
Welch Allyn Vision Express Holter Analysis System1
Welch Allyn Xscribe Cardiac Stress Testing System1
Welch Allyn Xscribe Cardiac Stress Testing System Firmware1
Baxter CVEs — newest first
CVESeverityScorePublishedSummary
CVE-2024-48974Critical9.32024-11-14The ventilator does not perform proper file integrity checks when adopting firmware updates. This makes it possible for an attacker to force unauthorized chang…
CVE-2024-48973Critical9.32024-11-14The debug port on the ventilator's serial interface is enabled by default. This could allow an attacker to send and receive messages over the debug port (which…
CVE-2024-48971Critical9.32024-11-14The Clinician Password and Serial Number Clinician Password are hard-coded into the ventilator in plaintext form. This could allow an attacker to obtain the pa…
CVE-2024-48970Critical9.32024-11-14The ventilator's microcontroller lacks memory protection. An attacker could connect to the internal JTAG interface and read or write to flash memory using an o…
CVE-2024-48967Critical10.02024-11-14The ventilator and the Service PC lack sufficient audit logging capabilities to allow for detection of malicious activity and subsequent forensic examination…
CVE-2024-48966Critical10.02024-11-14The software tools used by service personnel to test & calibrate the ventilator do not support user authentication. An attacker with access to the Service PC w…
CVE-2024-9834Critical9.32024-11-14Improper data protection on the ventilator's serial interface could allow an attacker to send and receive messages that result in unauthorized disclosure of in…
CVE-2024-9832Critical9.32024-11-14There is no limit on the number of failed login attempts permitted with the Clinician Password or the Serial Number Clinician Password. An attacker could execu…
CVE-2024-6796High8.22024-09-09In Baxter Connex health portal released before 8/30/2024, an improper access control vulnerability has been found that could allow an unauthenticated attacker…
CVE-2024-6795Critical10.02024-09-09In Connex health portal released before8/30/2024, SQL injection vulnerabilities were found that could have allowed an unauthenticated attacker to gain unauthor…
CVE-2024-51762024-05-31Insufficiently Protected Credentials vulnerability in Baxter Welch Allyn Configuration Tool may allow Remote Services with Stolen Credentials.This issue affect…
CVE-2024-12752024-05-31Use of Default Cryptographic Key vulnerability in Baxter Welch Allyn Connex Spot Monitor may allow Configuration/Environment Manipulation.This issue affects We…
CVE-2022-26394Medium5.52022-09-09The Baxter Spectrum WBM does not perform mutual authentication with the gateway server host. This may allow an attacker to perform a man in the middle attack t…
CVE-2022-26393Medium5.02022-09-09The Baxter Spectrum WBM is susceptible to format string attacks via application messaging. An attacker could use this to read memory in the WBM to access sensi…
CVE-2022-26392Low3.12022-09-09The Baxter Spectrum WBM (v16, v16D38) and Baxter Spectrum WBM (v17, v17D19, v20D29 to v20D32) when in superuser mode is susceptible to format string attacks vi…
CVE-2022-26390Medium4.22022-09-09The Baxter Spectrum Wireless Battery Module (WBM) stores network credentials and PHI (only applicable to Spectrum IQ pumps using auto programming) in unencrypt…
CVE-2021-43935High8.12021-12-15The impacted products, when configured to use SSO, are affected by an improper authentication vulnerability. This vulnerability allows the application to accep…
CVE-2020-12048High7.52020-06-29Phoenix Hemodialysis Delivery System SW 3.36 and 3.40, The Phoenix Hemodialysis device does not support data-in-transit encryption (e.g., TLS/SSL) when transmi…
CVE-2020-12047Critical9.82020-06-29The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24), when used with a Baxter Spectrum v8.x (model 35700BAX2) in a factory-default wireless config…
CVE-2020-12045Critical9.82020-06-29The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a Telnet ser…
CVE-2020-12043Critical9.82020-06-29The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when configured for wireless networking the FTP service operating on the WBM remains operatio…
CVE-2020-12041Critical9.42020-06-29The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) telnet Command-Line Interface, grants access to sensitive data stored on the WBM that permits…
CVE-2020-12040Critical9.82020-06-29Sigma Spectrum Infusion System v's6.x (model 35700BAX) and Baxter Spectrum Infusion System Version(s) 8.x (model 35700BAX2) at the application layer uses an un…
CVE-2020-12039Low2.42020-06-29Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hard…
CVE-2020-12037High7.52020-06-29Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when config…
CVE-2020-12036High7.52020-06-29Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when config…
CVE-2020-12035Medium4.92020-06-29Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The PrismaFlex device contains a hard-coded service password that provides access to biomedi…
CVE-2020-12032Critical9.12020-06-29Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems store device data with sensitive information in an unencrypted data…
CVE-2020-12024Medium6.12020-06-29Baxter ExactaMix EM 2400 versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 does not restrict access to the USB interface from…
CVE-2020-12020Medium6.12020-06-29Baxter ExactaMix EM 2400 Versions 1.10, 1.11, and 1.13 and ExactaMix EM1200 Versions 1.1, 1.2, and 1.4 does not restrict non administrative users from gaining…
CVE-2020-12016Critical9.82020-06-29Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix E…
CVE-2020-12012Medium6.12020-06-29Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix E…
CVE-2020-12008High7.52020-06-29Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems use cleartext messages to communicate order information with an ord…
CVE-2014-5433Critical9.82019-03-26An unauthenticated remote attacker may be able to execute commands to view wireless account credentials that are stored in cleartext on Baxter SIGMA Spectrum I…
CVE-2014-5432Critical9.82019-03-26Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 is remotely accessible via Port 22/SSH withou…
CVE-2014-5431Medium6.82019-03-26Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 contains a hard-coded password, which provide…
CVE-2014-5434Critical9.82019-03-26Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 has a default account with hard-coded credent…