Medtronic

35 CVEs across 264 Medtronic products. Browse Medtronic vulnerabilities, severities, and proof-of-concept exploits.

Medtronic products with known CVEs

ProductCVEs
Mycarelink Patient Monitor 249505
Mycarelink Patient Monitor 249525
24950 Mycarelink Monitor4
24952 Mycarelink Monitor4
29901 Encore Programmer4
Carelink Network4
Carelink Network4
Valleylab Ft10 Energy Platform4
Valleylab Ft10 Energy Platform Firmware4
Valleylab Ft10 Energy Platform (Vlft10gen)4
2090 Carelink Programmer3
2090 Carelink Programmer3
2090 Carelink Programmer Firmware3
Carelink 2090 Programmer3
Mycarelink Smart Model 250003
Mycarelink Smart Model 25000 Firmware3
Smart Model 25000 Patient Reader3
24950 Mycarelink Monitor2
24950 Mycarelink Monitor Firmware2
24952 Mycarelink Monitor2
24952 Mycarelink Monitor Firmware2
8870 N’vision Removable Application Card2
Amplia Crt-D2
Amplia Crt-D2
Amplia Crt-D Firmware2
Brava Crt-D2
Carelink 20902
Carelink 2090 Firmware2
Carelink Monitor2
Claria Crt-D2
Claria Crt-D2
Claria Crt-D Firmware2
Compia Crt-D2
Compia Crt-D2
Compia Crt-D Firmware2
Concerto Crt-D2
Concerto Crt-D2
Concerto Crt-D Firmware2
Concerto Ii Crt-D2
Concerto Ii Crt-D2
Concerto Ii Crt-D Firmware2
Conexus Radio Frequency Telemetry Protocol2
Consulta Crt-D2
Consulta Crt-D2
Consulta Crt-D Firmware2
Evera Icd2
Evera Icd2
Evera Icd Firmware2
Maximo Ii Crt-D2
Maximo Ii Icd2
Medtronic CVEs — newest first
CVESeverityScorePublishedSummary
CVE-2025-4397Medium6.82026-05-07Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials to modify encr…
CVE-2025-4386Medium6.82026-05-07Medtronic MyCareLink Patient Monitor has an internal serial interface, which allows an attacker with physical access to access a login prompt via a UART termin…
CVE-2025-12997Low2.22025-12-04Insecure Direct Object Reference vulnerability in Medtronic CareLink Network which allows an authenticated attacker with access to specific device and user inf…
CVE-2025-12996Medium4.12025-12-04Medtronic CareLink Network allows a local attacker with access to log files on an internal API server to view plaintext passwords from errors logged under cert…
CVE-2025-12995High8.12025-12-04Medtronic CareLink Network allows an unauthenticated remote attacker to perform a brute force attack on an API endpoint that could be used to determine a valid…
CVE-2025-12994Medium5.32025-12-04Medtronic CareLink Network allows an unauthenticated remote attacker to initiate a request for security questions to an API endpoint that could be used to dete…
CVE-2025-4395Medium6.82025-07-24Medtronic MyCareLink Patient Monitor has a built-in user account with an empty password, which allows an attacker with physical access to log in with no passwo…
CVE-2025-4394Medium6.82025-07-24Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files…
CVE-2025-4393Medium6.52025-07-24Medtronic MyCareLink Patient Monitor has an internal service that deserializes data, which allows a local attacker to interact with the service by crafting a b…
CVE-2023-31222Critical9.82023-06-29Deserialization of untrusted data in Microsoft Messaging Queuing Service in Medtronic's Paceart Optima versions 1.11 and earlier on Windows allows an unauthori…
CVE-2023-25931Medium6.42023-03-01Medtronic identified that the Pelvic Health clinician apps, which are installed on the Smart Programmer mobile device, have a password vulnerability that requi…
CVE-2022-32537Medium4.82022-12-12A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is b…
CVE-2020-27252High8.82020-12-14Medtronic MyCareLink Smart 25000 is vulnerable to a race condition in the MCL Smart Patient Reader software update system, which allows unsigned firmware to…
CVE-2020-25187High8.82020-12-14Medtronic MyCareLink Smart 25000 is  vulnerable when an authenticated attacker runs a debug command, which can be sent to the patient reader and cause a heap…
CVE-2020-25183High8.02020-12-14Medtronic MyCareLink Smart 25000 contains an authentication protocol vulnerability where the method used to authenticate between the MCL Smart Patient Reader…
CVE-2019-13543Medium5.82019-11-08Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energ…
CVE-2019-13539High7.02019-11-08Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energ…
CVE-2019-13535Medium4.62019-11-08In Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) version 2.1.0 and lower and version 2.0.3 and lower, and Valleylab LS10 Energy Platform (VLLS10GEN—not…
CVE-2019-13531Medium4.82019-11-08In Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) version 2.1.0 and lower and version 2.0.3 and lower, and Valleylab LS10 Energy Platform (VLLS10GEN—not…
CVE-2019-10964High7.12019-06-28Medtronic MiniMed Insulin Pumps are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters…
CVE-2019-6540Medium6.52019-03-26The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer…
CVE-2019-6538Critical9.32019-03-25The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer…
CVE-2018-18984Medium4.62018-12-14Medtronic CareLink and Encore Programmers do not encrypt or do not sufficiently encrypt sensitive PII and PHI information while at rest .
CVE-2018-14781Medium5.32018-08-13Medtronic MiniMed MMT devices when paired with a remote controller and having the “easy bolus” and “remote bolus” options enabled (non-default), are vulnerab…
CVE-2018-10634Medium4.82018-08-13Communications between Medtronic MiniMed MMT pumps and wireless accessories are transmitted in cleartext. A sufficiently skilled attacker could capture these t…
CVE-2018-10626Medium4.42018-08-10Medtronic MyCareLink Patient Monitor’s update service does not sufficiently verify the authenticity of the data uploaded. An attacker who obtains per-product…
CVE-2018-10622Medium5.22018-08-10Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials for network au…
CVE-2018-10631Medium6.32018-07-13The 8840 Clinician Programmer executes the application program from the 8870 Application Card. An attacker with physical access to an 8870 Application Card and…
CVE-2018-8870Medium6.42018-07-03Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. An attacker with physical access can remove th…
CVE-2018-8868Medium6.22018-07-03Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor's communication interfaces…
CVE-2018-10596High7.12018-07-03Medtronic 2090 CareLink Programmer uses a virtual private network connection to securely download updates. It does not verify it is still connected to this v…
CVE-2018-8849Medium4.62018-05-18Medtronic N'Vision Clinician Programmer 8840 N'Vision Clinician Programme and 8870 N'Vision removable Application Card do not encrypt PII and PHI while at rest.
CVE-2018-5448Medium4.82018-05-04Medtronic 2090 CareLink Programmer’s software deployment network contains a directory traversal vulnerability that could allow an attacker to read files on the…
CVE-2018-5446Medium4.92018-05-04Medtronic 2090 CareLink Programmer uses a per-product username and password that is stored in a recoverable format.
CVE-2011-33862011-09-02Unspecified vulnerability in Medtronic Paradigm wireless insulin pump 512, 522, 712, and 722 allows remote attackers to modify the delivery of an insulin bolus…