Siemens
Page 5 of 20 — Siemens CVEs from a corpus of 1980, newest first, with CVSS severity and publication dates.
| CVE | Severity | Score | Published | Summary |
|---|---|---|---|---|
CVE-2024-52567 | High | 7.8 | 2024-11-18 | A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12)… |
CVE-2024-52566 | High | 7.8 | 2024-11-18 | A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12)… |
CVE-2024-52565 | High | 7.8 | 2024-11-18 | A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12)… |
CVE-2024-50572 | High | 7.2 | 2024-11-12 | A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2… |
CVE-2024-50561 | Medium | 4.3 | 2024-11-12 | A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2… |
CVE-2024-50560 | Low | 3.1 | 2024-11-12 | A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2… |
CVE-2024-50559 | Medium | 4.3 | 2024-11-12 | A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2… |
CVE-2024-50558 | Medium | 4.3 | 2024-11-12 | A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2… |
CVE-2024-50557 | High | 7.2 | 2024-11-12 | A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2… |
CVE-2024-50313 | Medium | 5.3 | 2024-11-12 | A vulnerability has been identified in Mendix Runtime V10 (All versions < V10.16.0 only if the basic authentication mechanism is used by the application), Mend… |
CVE-2024-50310 | High | 7.5 | 2024-11-12 | A vulnerability has been identified in SIMATIC CP 1543-1 V4.0 (6GK7543-1AX10-0XE0) (All versions >= V4.0.44 < V4.0.50). Affected devices do not properly handle… |
CVE-2024-47942 | High | 7.3 | 2024-11-12 | A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 9). The affected applications suffer from a DLL hijacking vulnerability… |
CVE-2024-47941 | High | 7.8 | 2024-11-12 | A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 9). The affected applications contain an out of bounds read past the end… |
CVE-2024-47940 | High | 7.8 | 2024-11-12 | A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 9). The affected applications contain an out of bounds read past the end… |
CVE-2024-47808 | High | 8.4 | 2024-11-12 | A vulnerability has been identified in SINEC NMS (All versions < V3.0 SP1). The affected application contains a database function, that does not properly restr… |
CVE-2024-47783 | High | 7.8 | 2024-11-12 | A vulnerability has been identified in SIPORT (All versions < V3.4.0). The affected application improperly assigns file permissions to installation folders. … |
CVE-2024-46894 | Medium | 6.3 | 2024-11-12 | A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly validate authorization of a use… |
CVE-2024-46892 | Medium | 4.9 | 2024-11-12 | A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly invalidate sessions when the as… |
CVE-2024-46891 | Medium | 5.3 | 2024-11-12 | A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly restrict the size of generated… |
CVE-2024-46890 | Critical | 9.1 | 2024-11-12 | A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly validate input sent to specific… |
CVE-2024-46889 | Medium | 5.3 | 2024-11-12 | A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application uses hard-coded cryptographic key material to obf… |
CVE-2024-46888 | Critical | 9.9 | 2024-11-12 | A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly sanitize user provided paths fo… |
CVE-2024-44102 | Critical | 10.0 | 2024-11-12 | A vulnerability has been identified in PP TeleControl Server Basic 1000 to 5000 V3.1 (6NH9910-0AA31-0AE1) (All versions < V3.1.2.1 with redundancy configured)… |
CVE-2024-36140 | Medium | 6.8 | 2024-11-12 | A vulnerability has been identified in OZW672 (All versions < V5.2), OZW772 (All versions < V5.2). The user accounts tab of affected devices is vulnerable to s… |
CVE-2024-29119 | High | 7.8 | 2024-11-12 | A vulnerability has been identified in Spectrum Power 7 (All versions < V24Q3). The affected product contains several root-owned SUID binaries that could allow… |
CVE-2023-32736 | High | 7.3 | 2024-11-12 | A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SI… |
CVE-2024-47904 | High | 7.8 | 2024-10-23 | A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 on… |
CVE-2024-47903 | Medium | 5.8 | 2024-10-23 | A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 on… |
CVE-2024-47902 | High | 7.2 | 2024-10-23 | A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 on… |
CVE-2024-47901 | Critical | 10.0 | 2024-10-23 | A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 on… |
CVE-2024-49894 | High | 7.1 | 2024-10-21 | In the Linux kernel, the following vulnerability has been resolved: drm/amd/display: Fix index out of bounds in degamma hardware format translation Fixes ind… |
CVE-2024-47565 | Medium | 4.3 | 2024-10-08 | A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). The affected application does not properly validate that user input comp… |
CVE-2024-47563 | Medium | 5.3 | 2024-10-08 | A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). The affected application does not properly validate a file path that is… |
CVE-2024-47562 | High | 8.8 | 2024-10-08 | A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). The affected application does not properly neutralize special elements i… |
CVE-2024-47553 | Critical | 9.9 | 2024-10-08 | A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). The affected application does not properly validate user input to the ``… |
CVE-2024-47196 | Medium | 6.7 | 2024-10-08 | A vulnerability has been identified in ModelSim (All versions < V2025.2), Questa (All versions < V2025.2). vsimk.exe in affected applications allows a specific… |
CVE-2024-47195 | Medium | 6.7 | 2024-10-08 | A vulnerability has been identified in ModelSim (All versions < V2024.3), Questa (All versions < V2024.3). gdb.exe in affected applications allows a specific e… |
CVE-2024-47194 | Medium | 6.7 | 2024-10-08 | A vulnerability has been identified in ModelSim (All versions < V2024.3), Questa (All versions < V2024.3). vish2.exe in affected applications allows a specific… |
CVE-2024-47046 | High | 7.8 | 2024-10-08 | A vulnerability has been identified in Simcenter Femap V2306 (All versions), Simcenter Femap V2401 (All versions), Simcenter Femap V2406 (All versions). The af… |
CVE-2024-46887 | Medium | 5.3 | 2024-10-08 | The web server of affected devices do not properly authenticate user request to the '/ClientArea/RuntimeInfoData.mwsl' endpoint. This could allow an unauthenti… |
CVE-2024-46886 | Medium | 4.7 | 2024-10-08 | The web server of affected devices does not properly validate input that is used for a user redirection. This could allow an attacker to make the server redire… |
CVE-2024-45476 | Low | 3.3 | 2024-10-08 | A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12)… |
CVE-2024-45475 | High | 7.8 | 2024-10-08 | A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12)… |
CVE-2024-45474 | High | 7.8 | 2024-10-08 | A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12)… |
CVE-2024-45473 | High | 7.8 | 2024-10-08 | A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12)… |
CVE-2024-45472 | High | 7.8 | 2024-10-08 | A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12)… |
CVE-2024-45471 | High | 7.8 | 2024-10-08 | A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12)… |
CVE-2024-45470 | High | 7.8 | 2024-10-08 | A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12)… |
CVE-2024-45469 | High | 7.8 | 2024-10-08 | A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12)… |
CVE-2024-45468 | High | 7.8 | 2024-10-08 | A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12)… |
CVE-2024-45467 | High | 7.8 | 2024-10-08 | A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12)… |
CVE-2024-45466 | High | 7.8 | 2024-10-08 | A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12)… |
CVE-2024-45465 | High | 7.8 | 2024-10-08 | A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12)… |
CVE-2024-45464 | High | 7.8 | 2024-10-08 | A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12)… |
CVE-2024-45463 | High | 7.8 | 2024-10-08 | A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12)… |
CVE-2024-41981 | High | 7.8 | 2024-10-08 | A vulnerability has been identified in Simcenter Femap V2306 (All versions), Simcenter Femap V2401 (All versions), Simcenter Femap V2406 (All versions). The af… |
CVE-2024-41902 | High | 7.8 | 2024-10-08 | A vulnerability has been identified in JT2Go (All versions < V2406.0003). The affected application contains a stack-based buffer overflow vulnerability that co… |
CVE-2024-41798 | Critical | 9.8 | 2024-10-08 | A vulnerability has been identified in SENTRON 7KM PAC3200 (All versions). Affected devices only provide a 4-digit PIN to protect from administrative access vi… |
CVE-2023-52952 | High | 8.5 | 2024-10-08 | A vulnerability has been identified in HiMed Cockpit 12 pro (J31032-K2017-H259) (All versions >= V11.5.1 < V11.6.2), HiMed Cockpit 14 pro+ (J31032-K2017-H435)… |
CVE-2024-34057 | High | 7.5 | 2024-09-18 | Triangle Microworks TMW IEC 61850 Client source code libraries before 12.2.0 lack a buffer size check when processing received messages. The resulting buffer o… |
CVE-2024-45032 | Critical | 10.0 | 2024-09-10 | A vulnerability has been identified in Industrial Edge Management Pro (All versions < V1.9.5), Industrial Edge Management Virtual (All versions < V2.3.1-1). Af… |
CVE-2024-44087 | High | 8.6 | 2024-09-10 | A vulnerability has been identified in Automation License Manager V5 (All versions), Automation License Manager V6.0 (All versions < V6.0 SP12 Upd3), Automatio… |
CVE-2024-43781 | Medium | 5.5 | 2024-09-10 | A vulnerability has been identified in SINUMERIK 828D V4 (All versions < V4.95 SP3), SINUMERIK 840D sl V4 (All versions < V4.95 SP3 in connection with using Cr… |
CVE-2024-43647 | High | 7.5 | 2024-09-10 | A vulnerability has been identified in SIMATIC S7-200 SMART CPU CR40 (6ES7288-1CR40-0AA0) (All versions), SIMATIC S7-200 SMART CPU CR60 (6ES7288-1CR60-0AA0) (A… |
CVE-2024-42345 | Medium | 4.3 | 2024-09-10 | A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP2). The affected application does not properly handle user session e… |
CVE-2024-42344 | Medium | 4.4 | 2024-09-10 | A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.2 SP2). The affected application inserts sensitive information into a lo… |
CVE-2024-41171 | High | 8.8 | 2024-09-10 | A vulnerability has been identified in SINUMERIK 828D V4 (All versions), SINUMERIK 828D V5 (All versions < V5.24), SINUMERIK 840D sl V4 (All versions), SINUMER… |
CVE-2024-41170 | High | 7.8 | 2024-09-10 | A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0015), Tecnomatix Plant Simulation V2404 (All versions < V2404.0… |
CVE-2024-37995 | Low | 2.7 | 2024-09-10 | A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0)… |
CVE-2024-37994 | Medium | 4.3 | 2024-09-10 | A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0)… |
CVE-2024-37993 | Medium | 5.3 | 2024-09-10 | A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0)… |
CVE-2024-37992 | Medium | 4.9 | 2024-09-10 | A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0)… |
CVE-2024-37991 | Medium | 5.3 | 2024-09-10 | A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0)… |
CVE-2024-37990 | Medium | 6.5 | 2024-09-10 | A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0)… |
CVE-2024-35783 | Critical | 9.1 | 2024-09-10 | A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions < V2020 SP2 Update 5), SIMATIC Informat… |
CVE-2024-33698 | Critical | 9.8 | 2024-09-10 | A vulnerability has been identified in Opcenter Quality (All versions < V2406), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMA… |
CVE-2024-32006 | Medium | 4.3 | 2024-09-10 | A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.2 SP2). The affected application does not expire the user session on reb… |
CVE-2023-49069 | Medium | 5.3 | 2024-09-10 | A vulnerability has been identified in Mendix Runtime V10 (All versions < V10.17.0 only if the basic authentication mechanism is used by the application), Mend… |
CVE-2023-30756 | Medium | 5.9 | 2024-09-10 | A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All ve… |
CVE-2023-30755 | Medium | 4.4 | 2024-09-10 | A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All ve… |
CVE-2023-28827 | Medium | 5.9 | 2024-09-10 | A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All ve… |
CVE-2024-41978 | Medium | 6.5 | 2024-08-13 | A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.1), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2… |
CVE-2024-41977 | High | 7.1 | 2024-08-13 | A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.1), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2… |
CVE-2024-41976 | High | 7.2 | 2024-08-13 | A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.1), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2… |
CVE-2024-41941 | Medium | 4.3 | 2024-08-13 | A vulnerability has been identified in SINEC NMS (All versions < V3.0). The affected application does not properly enforce authorization checks. This could all… |
CVE-2024-41940 | Critical | 9.1 | 2024-08-13 | A vulnerability has been identified in SINEC NMS (All versions < V3.0). The affected application does not properly validate user input to a privileged command… |
CVE-2024-41939 | High | 8.8 | 2024-08-13 | A vulnerability has been identified in SINEC NMS (All versions < V3.0). The affected application does not properly enforce authorization checks. This could all… |
CVE-2024-41938 | Medium | 5.5 | 2024-08-13 | A vulnerability has been identified in SINEC NMS (All versions < V3.0). The importCertificate function of the SINEC NMS Control web application contains a path… |
CVE-2024-41908 | High | 7.8 | 2024-08-13 | A vulnerability has been identified in NX (All versions < V2406.3000). The affected applications contains an out of bounds read vulnerability while parsing spe… |
CVE-2024-41907 | Medium | 4.2 | 2024-08-13 | A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V2.0). The affected application is missing general HTTP secu… |
CVE-2024-41906 | Medium | 4.8 | 2024-08-13 | A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V2.0). The affected application does not properly handle cac… |
CVE-2024-41905 | Medium | 6.8 | 2024-08-13 | A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V2.0). The affected application do not have access control f… |
CVE-2024-41904 | High | 7.5 | 2024-08-13 | A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V2.0). The affected application do not properly enforce rest… |
CVE-2024-41903 | Medium | 6.6 | 2024-08-13 | A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V2.0). The affected application mounts the container's root… |
CVE-2024-41683 | Medium | 5.3 | 2024-08-13 | A vulnerability has been identified in Location Intelligence family (All versions < V4.4). Affected products do not properly enforce a strong user password pol… |
CVE-2024-41682 | Medium | 5.3 | 2024-08-13 | A vulnerability has been identified in Location Intelligence family (All versions < V4.4). Affected products do not properly enforce restriction of excessive… |
CVE-2024-41681 | Medium | 6.7 | 2024-08-13 | A vulnerability has been identified in Location Intelligence family (All versions < V4.4). The web server of affected products is configured to support weak ci… |
CVE-2024-39922 | Medium | 4.6 | 2024-08-13 | A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6… |
CVE-2024-36398 | High | 7.8 | 2024-08-13 | A vulnerability has been identified in SINEC NMS (All versions < V3.0). The affected application executes a subset of its services as `NT AUTHORITY\SYSTEM`. Th… |
CVE-2023-7066 | High | 7.8 | 2024-08-12 | The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PDF files. This could allow an… |