Improper input validation in Siemens Sipass Integrated Ac5102 (Acc-G2)

CVE-2025-27494

A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V6.4.9), SiPass integrated ACC-AP (All versions < V6.4.9). Affected devices improperly sanitize input for the pubkey endpoint of the REST API. This could allow an authenticated remote administrator to escalate privileges by injecting arbitrary commands that are executed with root privileges.

Vulnerability class: Drupalgeddon 2 (CVE-2018-7600)

Published · last modified .

CVSS v3 metric

CVSS v3 base score 9.1 (Critical). Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H.

EPSS exploit prediction

EPSS 0.005, 43.4th percentile (scored ); unchanged over 30 days. About EPSS.

Affected products

Weakness classification (CWE)

Public exploits and proof-of-concept code

Also mentioned in 1 other repository (fkie-cad/nvd-json-data-feeds). These reference the CVE in a list, notes or a scanner and are not exploit code for it.

References