Buffer overflow in Siemens Teamcenter Visualization
CVE-2024-53041
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain a stack based overflow vulnerability while parsing specially crafted WRL files.
This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25000)
Vulnerability class: Buffer Overflow
Published · last modified .
CVSS v3 metric
CVSS v3 base score 7.8 (High). Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H.
EPSS exploit prediction
EPSS 0.002, 7.5th percentile (scored ); unchanged over 30 days. About EPSS.
Affected products
- Siemens Teamcenter Visualization
- Siemens Teamcenter Visualization V14.2 — versions 0
- Siemens Teamcenter Visualization V14.3 — versions 0
- Siemens Teamcenter Visualization V2312 — versions 0
- Siemens Tecnomatix Plant Simulation
- Siemens Tecnomatix Plant Simulation V2302 — versions 0
- Siemens Tecnomatix Plant Simulation V2404 — versions 0
Weakness classification (CWE)
Public exploits and proof-of-concept code
Also mentioned in 1 other repository (fkie-cad/nvd-json-data-feeds). These reference the CVE in a list, notes or a scanner and are not exploit code for it.
References
- cert-portal.siemens.com/productcert/html/ssa-583523.html (Vendor Advisory)
- cert-portal.siemens.com/productcert/html/ssa-645131.html (Vendor Advisory)