Siemens Simatic_wincc_runtime
13 CVEs affecting Siemens Simatic_wincc_runtime. Latest disclosed: 2022-11-08. Critical: 1, High: 5.
| CVE | Severity | Score | Published | Summary |
|---|---|---|---|---|
CVE-2019-6572 | Critical | 9.1 | 2019-05-14 | A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All ve… |
CVE-2018-13814 | High | 8.8 | 2018-12-13 | A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V1… |
CVE-2018-13813 | High | 8.1 | 2018-12-13 | A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All vers… |
CVE-2021-40142 | High | 7.5 | 2021-08-27 | In OPC Foundation Local Discovery Server (LDS) before 1.04.402.463, remote attackers can cause a denial of service (DoS) by sending carefully crafted messages… |
CVE-2018-13812 | High | 7.5 | 2018-12-13 | A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All vers… |
CVE-2019-10935 | High | 7.2 | 2019-07-11 | A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC… |
CVE-2022-30694 | Medium | 6.5 | 2022-11-08 | The login endpoint /FormLogin in affected web services does not apply proper origin checking. This could allow authenticated remote attackers to track the a… |
CVE-2019-6576 | Medium | 6.5 | 2019-05-14 | A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All ve… |
CVE-2016-7165 | Medium | 6.4 | 2016-11-15 | A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC… |
CVE-2019-10929 | Medium | 5.9 | 2019-08-13 | A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), S… |
CVE-2019-6577 | Medium | 5.4 | 2019-05-14 | A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All ve… |
CVE-2017-6867 | Medium | 4.9 | 2017-05-11 | A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 be… |
CVE-2011-3321 | | 2011-09-16 | Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advan… |