Improper input validation in Siemens Simatic Hmi Comfort Outdoor Panels

CVE-2018-13814

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

EPSS: 0.017 (74.6th percentile) — read the EPSS interpretation.

CVSS v3 metric

CVSS v3 base score 8.8 (High). Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H.

Affected products

Weakness classification (CWE)

References

Frequently asked questions

What is CVE-2018-13814?
CVE-2018-13814 is a high-severity vulnerability in Siemens Simatic Hmi Comfort Outdoor Panels, classified under HTTP Response Splitting. CVSS score: 8.8/10. Published 2018-12-13.
How severe is CVE-2018-13814?
High severity. CVSS v3 base score is 8.8 out of 10.