Vulnerability in Siemens Simatic Hmi Comfort Outdoor Panels
CVE-2019-6576
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of the affected device. The vulnerability could impact the confidentiality of the communication between the affected device and a legitimate user. At the time of advisory publication no public exploitation of the security vulnerability was known.
Vulnerability class: POODLE (CVE-2014-3566)
Published · last modified .
CVSS v3 metric
CVSS v3 base score 6.5 (Medium). Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N.
EPSS exploit prediction
EPSS: 0.017 (77.5th percentile), scored .
Low probability of exploitation in the next 30 days, but still tracked. 78th percentile — 77.5% of CVEs in the catalogue have a lower EPSS than this one. How to read EPSS.
EPSS over last 30 days · oldest: 0.017 · newest: 0.017 · change: +0.001
Affected products
- Siemens Simatic Hmi Comfort Outdoor Panels
- Siemens Simatic Hmi Comfort Outdoor Panels Firmware
- Siemens Simatic Hmi Comfort Panels
- Siemens Simatic Hmi Comfort Panels Firmware
- Siemens Simatic Hmi Ktp Mobile Panels Ktp400f
- Siemens Simatic Hmi Ktp Mobile Panels Ktp400f Firmware
- Siemens Simatic Hmi Ktp Mobile Panels Ktp700
- Siemens Simatic Hmi Ktp Mobile Panels Ktp700f
- Siemens Simatic Hmi Ktp Mobile Panels Ktp700f Firmware
- Siemens Simatic Hmi Ktp Mobile Panels Ktp700 Firmware
Weakness classification (CWE)
References
Frequently asked questions
- What is CVE-2019-6576?
- CVE-2019-6576 is a medium-severity vulnerability in Siemens Simatic Hmi Comfort Outdoor Panels, classified under Cryptographic Issues. CVSS score: 6.5/10. Published 2019-05-14.
- How severe is CVE-2019-6576?
- Medium severity. CVSS v3 base score is 6.5 out of 10.