Tenda F1203
34 CVEs affecting Tenda F1203. Latest disclosed: 2024-04-17. Critical: 7, High: 26.
| CVE | Severity | Score | Published | Summary |
|---|---|---|---|---|
CVE-2023-38940 | Critical | 9.8 | 2023-08-07 | Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi… |
CVE-2023-38936 | Critical | 9.8 | 2023-08-07 | Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_… |
CVE-2023-38934 | Critical | 9.8 | 2023-08-07 | Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName f… |
CVE-2023-38933 | Critical | 9.8 | 2023-08-07 | Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7… |
CVE-2023-38931 | Critical | 9.8 | 2023-08-07 | Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC… |
CVE-2023-38930 | Critical | 9.8 | 2023-08-07 | Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack ove… |
CVE-2022-46538 | Critical | 9.8 | 2022-12-20 | Tenda F1203 V2.0.1.6 was discovered to contain a command injection vulnerability via the mac parameter at /goform/WriteFacMac. |
CVE-2024-2979 | High | 8.8 | 2024-03-27 | A vulnerability classified as critical was found in Tenda F1203 2.0.1.6. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi… |
CVE-2024-2978 | High | 8.8 | 2024-03-27 | A vulnerability classified as critical has been found in Tenda F1203 2.0.1.6. This affects the function formSetCfm of the file /goform/setcfm. The manipulation… |
CVE-2024-2977 | High | 8.8 | 2024-03-27 | A vulnerability was found in Tenda F1203 2.0.1.6. It has been rated as critical. Affected by this issue is the function formQuickIndex of the file /goform/Quic… |
CVE-2024-2976 | High | 8.8 | 2024-03-27 | A vulnerability was found in Tenda F1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function R7WebsSecurityHandler of the… |
CVE-2024-32310 | High | 8.0 | 2024-04-17 | Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the PPW parameter of the fromWizardHandle function. |
CVE-2022-46551 | High | 7.5 | 2022-12-20 | Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the time parameter at /goform/saveParentControlInfo. |
CVE-2022-46550 | High | 7.5 | 2022-12-20 | Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the urls parameter at /goform/saveParentControlInfo. |
CVE-2022-46549 | High | 7.5 | 2022-12-20 | Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the deviceId parameter at /goform/saveParentControlInfo. |
CVE-2022-46548 | High | 7.5 | 2022-12-20 | Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the page parameter at /goform/DhcpListClient. |
CVE-2022-46547 | High | 7.5 | 2022-12-20 | Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the page parameter at /goform/VirtualSer. |
CVE-2022-46546 | High | 7.5 | 2022-12-20 | Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the entrys parameter at /goform/RouteStatic. |
CVE-2022-46545 | High | 7.5 | 2022-12-20 | Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the page parameter at /goform/NatStaticSetting. |
CVE-2022-46544 | High | 7.5 | 2022-12-20 | Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the cmdinput parameter at /goform/exeCommand. |