Siemens Simatic_s7-1200_cpu_1212fc_firmware
13 CVEs affecting Siemens Simatic_s7-1200_cpu_1212fc_firmware. Latest disclosed: 2022-12-13. Critical: 0, High: 4.
| CVE | Severity | Score | Published | Summary |
|---|---|---|---|---|
CVE-2021-40365 | High | 7.5 | 2022-12-13 | Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in th… |
CVE-2021-37205 | High | 7.5 | 2022-02-09 | A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl… |
CVE-2021-37204 | High | 7.5 | 2022-02-09 | A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9… |
CVE-2021-37185 | High | 7.5 | 2022-02-09 | A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl… |
CVE-2022-30694 | Medium | 6.5 | 2022-11-08 | The login endpoint /FormLogin in affected web services does not apply proper origin checking. This could allow authenticated remote attackers to track the a… |
CVE-2021-3449 | Medium | 5.9 | 2021-03-25 | An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the… |
CVE-2021-44694 | Medium | 5.5 | 2022-12-13 | Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in th… |
CVE-2021-44695 | Medium | 4.9 | 2022-12-13 | Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in th… |
CVE-2021-44693 | Medium | 4.9 | 2022-12-13 | Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in th… |
CVE-2013-2780 | | 2013-04-22 | Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to… | |
CVE-2013-0700 | | 2013-04-22 | Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to… | |
CVE-2012-3040 | | 2012-10-10 | Cross-site scripting (XSS) vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web sc… | |
CVE-2012-3037 | | 2012-09-25 | The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remot… |