Schneider Electric Se
Page 2 of 2 — Schneider Electric Se CVEs from a corpus of 118, newest first, with CVSS severity and publication dates.
| CVE | Severity | Score | Published | Summary |
|---|---|---|---|---|
CVE-2017-9966 | High | 7.1 | 2018-01-02 | A privilege escalation vulnerability exists in Schneider Electric's Pelco VideoXpert Enterprise versions 2.0 and prior. By replacing certain files, an unauthor… |
CVE-2017-9965 | Medium | 5.8 | 2018-01-02 | An exposure of sensitive information vulnerability exists in Schneider Electric's Pelco VideoXpert Enterprise versions 2.0 and prior. Using a directory travers… |
CVE-2017-9964 | Medium | 6.9 | 2018-01-02 | A Path Traversal issue was discovered in Schneider Electric Pelco VideoXpert Enterprise all versions prior to 2.1. By sniffing communications, an unauthorized… |
CVE-2017-9962 | High | 7.5 | 2017-09-26 | Schneider Electric's ClearSCADA versions released prior to August 2017 are susceptible to a memory allocation vulnerability, whereby malformed requests can be… |
CVE-2017-9961 | High | 7.8 | 2017-09-26 | A vulnerability exists in Schneider Electric's Pro-Face GP Pro EX version 4.07.000 that allows an attacker to execute arbitrary code. Malicious code installati… |
CVE-2017-9960 | Medium | 5.3 | 2017-09-26 | An information disclosure vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the system response to error… |
CVE-2017-9958 | High | 7.8 | 2017-09-26 | An improper access control vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which an improper handling of the… |
CVE-2017-9957 | Critical | 9.8 | 2017-09-26 | A vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the web service contains a hidden system account wit… |
CVE-2017-9956 | High | 7.3 | 2017-09-26 | An authentication bypass vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the system contains a hard-co… |
CVE-2017-7974 | Critical | 9.8 | 2017-09-26 | A path traversal information disclosure vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which an unauthentic… |
CVE-2017-7973 | Critical | 9.8 | 2017-09-26 | A SQL injection vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which an unauthenticated user can use calls… |
CVE-2017-7972 | Medium | 5.5 | 2017-09-26 | A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywher… |
CVE-2017-7971 | Medium | 6.5 | 2017-09-26 | A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywher… |
CVE-2017-7970 | Medium | 6.5 | 2017-09-26 | A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywher… |
CVE-2017-7969 | High | 8.8 | 2017-09-26 | A cross-site request forgery vulnerability exists on the Secure Gateway component of Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCAD… |
CVE-2017-7966 | High | 8.8 | 2017-06-07 | A DLL Hijacking vulnerability in the programming software in Schneider Electric's SoMachine HVAC v2.1.0 allows a remote attacker to execute arbitrary code on t… |
CVE-2017-7965 | High | 7.3 | 2017-06-07 | A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric's SoMachine HVAC v2.1.0 for Modicon M171/M172… |
CVE-2017-7967 | Medium | 5.5 | 2017-05-09 | All versions of VAMPSET software produced by Schneider Electric, prior to V2.2.189, are susceptible to a memory corruption vulnerability when a corrupted vf2 f… |