Vulnerability in N/a
CVE-2026-79417
Improper Access Control in ArgusMonitor.sys in Argotronic eGbR ArgusMonitor 7.4.02 and earlier allows local, low-privileged users to bypass device handle access restrictions via a TOCTOU condition in IRP_MJ_CREATE and send a crafted IOCTL 0x9C4024A8 request, causing denial-of-service.
Published · last modified .
CVSS v3 metric
CVSS v3 base score 5.3 (Medium). Vector: CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H.
EPSS exploit prediction
EPSS 0.002, 14.5th percentile (scored ); unchanged over 30 days. About EPSS.
Weakness classification (CWE)
Public exploits and proof-of-concept code
1 public repository with exploit or proof-of-concept code for this CVE:
- connorjaydunn/CVE-2026-79417 (last pushed 2026-09-25): CVE-2026-79417 PoC
References
This CVE has public exploit evidence. See the latest CVEs with public exploits.