Information disclosure in Paessler Gmbh Prtg Network Monitor
CVE-2026-4638
PRTG Network Monitor before version 26.2.120.1449 ships a demo EXE/Script sensor that multiplies two integer parameters using cscript.exe. If a non-numeric value is passed instead, cscript.exe raises a 'Type mismatch' runtime error that includes the offending parameter value in plaintext. PRTG provides a documented placeholder variable, %windowspassword, which resolves to the configured Windows/domain password used by PRTG and can be passed as a sensor parameter. Any PRTG user who is not restricted to read-only access and is permitted to create sensors (the default for non-read-only users) can pass %windowspassword as an argument to the demo VBScript sensor, triggering the type-mismatch error and causing PRTG to display the plaintext password in the sensor's error output.
Published · last modified .
EPSS exploit prediction
No EPSS score from FIRST.org yet. New CVEs usually get one within a few days; no score means no signal yet, not low risk. How EPSS works.
Affected products
Weakness classification (CWE)
References
- 551230f0-3615-47bd-b7cc-93e92e730bbf (third-party-advisory)
- 551230f0-3615-47bd-b7cc-93e92e730bbf (vendor-advisory)
- 551230f0-3615-47bd-b7cc-93e92e730bbf (patch)
- 551230f0-3615-47bd-b7cc-93e92e730bbf (product)