Vulnerability in Siemens Industrial Edge Management Pro V1

CVE-2026-33892

A vulnerability has been identified in Industrial Edge Management Pro V1 (All versions >= V1.7.6 < V1.15.17), Industrial Edge Management Pro V2 (All versions >= V2.0.0 < V2.1.1), Industrial Edge Management Virtual (All versions >= V2.2.0 < V2.8.0). Affected management systems do not properly enforce user authentication on remote connections to devices. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that the attacker has identified the header and port used for remote connections to devices and that the remote connection feature is enabled for the device. Exploitation allows the attacker to tunnel to the device. Security features on this device itself (e.g. app specific authentication) are not affected.

EPSS: 0.002 (11.3th percentile) — read the EPSS interpretation.

CVSS v3 metric

CVSS v3 base score 7.1 (High). Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L.

Affected products

Weakness classification (CWE)

References

Frequently asked questions

What is CVE-2026-33892?
CVE-2026-33892 is a high-severity vulnerability in Siemens Industrial Edge Management Pro V1, classified under Authentication Bypass by Primary Weakness. CVSS score: 7.1/10. Published 2026-04-14.
How severe is CVE-2026-33892?
High severity. CVSS v3 base score is 7.1 out of 10.