Vulnerability in Siemens Sicam Siapp Sdk
CVE-2026-25572
A vulnerability has been identified in SICAM SIAPP SDK (All versions < V2.1.7). The SICAM SIAPP SDK server component does not enforce maximum length checks on certain variables before use. This could allow an attacker to send an oversized input that could trigger a stack overflow crashing the process and potentially causing denial of service.
Published · last modified .
CVSS v3 metric
CVSS v3 base score 5.1 (Medium). Vector: CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H.
EPSS exploit prediction
EPSS: 0.001 (1.8th percentile), scored .
Very low probability of exploitation in the next 30 days; routine patching cadence is appropriate. 2nd percentile — 1.8% of CVEs in the catalogue have a lower EPSS than this one. How to read EPSS.
EPSS over last 30 days · oldest: 0.001 · newest: 0.001 · change: +0.000
Affected products
- Siemens Sicam Siapp Sdk — versions 0
- Siemens Sicam Siapp Sdk
Weakness classification (CWE)
References
- cert-portal.siemens.com/productcert/html/ssa-903736.html (Vendor Advisory)
Frequently asked questions
- What is CVE-2026-25572?
- CVE-2026-25572 is a medium-severity vulnerability in Siemens Sicam Siapp Sdk, classified under Improper Handling of Length Parameter Inconsistency. CVSS score: 5.1/10. Published 2026-03-10.
- How severe is CVE-2026-25572?
- Medium severity. CVSS v3 base score is 5.1 out of 10.