Buffer overflow in Tenda Ac12
CVE-2026-19821
A vulnerability was determined in Tenda AC12 15.03.06.23_multi_TD01. This vulnerability affects the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg of the component httpd web management interface. This manipulation of the argument rebootTime causes buffer overflow. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized.
Vulnerability class: Buffer Overflow
Published · last modified .
CVSS v3 metric
CVSS v3 base score 8.8 (High). Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H.
EPSS exploit prediction
EPSS 0.009, 58.9th percentile (scored ); unchanged over 30 days. About EPSS.
Affected products
- Tenda Ac12 — versions 15.03.06.23_multi_TD01
Weakness classification (CWE)
References
- github.com/lipenghai/iot_bug/blob/main/Tenda/AC12/4.md (exploit)
- CVE-2026-19821 | CVE Analysis and Report (third-party-advisory)
- Submit #868922 | Tenda AC12 US_AC1206V1.0RTL_V15.03.06.23_multi_TD01.bin Buffer Overflow (third-party-advisory)
- VDB-389954 | Tenda AC12 httpd web management interface SetSysAutoRebbotCfg formSetRebootTimer buffer overflow (technical-description, vdb-entry)
- VDB-389954 | CTI Indicators (IOB, IOC, IOA) (signature, permissions-required)
- www.tenda.com.cn/ (product)