Auth bypass in IBM Power Hardware Management Console \(7063-Cr2\) Firmware
CVE-2026-17429
- CVSS v3
- 8.1 High
- Public exploits
- None known
- EPSS
- 0.002 · 4.3th percentile
- Published
- 2026-08-19
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 - OP940.81 (Power HMC) is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can write arbitrary data to hardware control registers, allowing full control over the host system and all hosted partitions, resulting in a confidentiality, integrity, and availability impact.
Vulnerability class: Broken Access Control
Published · last modified .
CVSS v3 metric
CVSS v3 base score 8.1 (High). Vector: CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:L/I:H/A:H.
- Attack Vector
- Local
AV:L - Attack Complexity
- Low
AC:L - Privileges Required
- High
PR:H - User Interaction
- None
UI:N - Scope
- Changed
S:C - Confidentiality
- Low
C:L - Integrity
- High
I:H - Availability
- High
A:H
EPSS exploit prediction
EPSS 0.002, 4.3th percentile (last changed ); unchanged over 30 days. About EPSS.
Affected products
- IBM Power Hardware Management Console \(7063-Cr2\) Firmware
- IBM Power System Ac922 \(8335-Gth\) Firmware
- IBM Power System Ac922 \(8335-Gtx\) Firmware
- IBM Power System E1050 \(9043-Mrx\) Firmware
- IBM Power System E1080 \(9080-Hex\) Firmware
- IBM Power System E1150 \(9043-Mru\) Firmware — versions fw1120.00
- IBM Power System E1180 \(9080-Heu\) Firmware — versions fw1120.00
- IBM Power System E950 \(9040-Mr9\) Firmware
- IBM Power System E980 \(9080-M9s\) Firmware
- IBM Power System H922 \(9223-22s\) Firmware
Weakness classification (CWE)
References
- www.ibm.com/support/pages/node/7283218 (vendor-advisory, patch, Vendor Advisory)