RCE in Signalwire Freeswitch

CVE-2026-116786

FreeSWITCH is a Software Defined Telecom Stack enabling the digital transformation from proprietary telecom switches to a software implementation that runs on any commodity hardware. Prior to 1.11.2, sofia_handle_sip_i_refer() placed raw Refer-To URI parameters and headers inside a sip_invite_params channel-variable block passed to switch_ivr_originate(). The originate parser treated a comma in the attacker-controlled value as a variable separator, allowing an authenticated caller on a bridged call to inject arbitrary variables into a newly originated leg. An injected execute_on_originate value could invoke the system dialplan application before answer and execute operating-system commands with the FreeSWITCH process privileges. SIP REFER is enabled by default, and the sender needs only a registered account and a call that takes the off-box transfer path, not administrative or Event Socket access. This issue is fixed in version 1.11.2.

Vulnerability class: Command Injection (OS Command Injection)

Published · last modified .

CVSS v3 metric

CVSS v3 base score 8.8 (High). Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H.

EPSS exploit prediction

No EPSS score from FIRST.org yet. New CVEs usually get one within a few days; no score means no signal yet, not low risk. How EPSS works.

Affected products

Weakness classification (CWE)

References

Frequently asked questions

What is CVE-2026-116786?
CVE-2026-116786 is a high-severity vulnerability in Signalwire Freeswitch, classified under Command Injection. CVSS score: 8.8/10. Published 2026-11-05.
How severe is CVE-2026-116786?
High severity. CVSS v3 base score is 8.8 out of 10.