Buffer overflow in Tenda Hg10
CVE-2026-11499
A vulnerability was determined in Tenda HG7, HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote.
Vulnerability class: Buffer Overflow
Published · last modified .
CVSS v3 metric
CVSS v3 base score 9.8 (Critical). Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.
EPSS exploit prediction
EPSS 0.066, 94.0th percentile (scored ); unchanged over 30 days. About EPSS.
Affected products
- Tenda Hg10 — versions 300001138_en_xpon
- Tenda Hg7 — versions 300001138_en_xpon
- Tenda Hg9 — versions 300001138_en_xpon
Weakness classification (CWE)
Public exploits and proof-of-concept code
3 public repositories with exploit or proof-of-concept code for this CVE:
- 0xBlackash/CVE-2026-11499 (2 stars, last pushed 2026-06-08): CVE-2026-11499
- 0xredash/CVE-2026-11499 (2 stars, last pushed 2026-06-08): CVE-2026-11499
- ashrafzaryouh/CVE-2026-11499 (2 stars, last pushed 2026-06-08): CVE-2026-11499
References
- github.com/ssaaaa1234/Tenda-HG10-formDOMAINBLK-stack-overflow-2 (related, broken-link)
- CVE-2026-11499 | CVE Analysis and Report (third-party-advisory)
- Submit #834888 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow (third-party-advisory)
- VDB-369119 | Tenda HG7/HG9/HG10 formDOMAINBLK stack-based overflow (technical-description, vdb-entry)
- VDB-369119 | CTI Indicators (IOB, IOC, IOA) (signature, permissions-required)
- www.tenda.com.cn/ (product)
- Submit #888875 | Tenda HG10 HG7_HG9_HG10re_300001138 Denial of Service (Duplicate) (third-party-advisory)
This CVE has public exploit evidence. See the latest CVEs with public exploits.