RCE in Lantronix Eds5000 Series
CVE-2025-67037
An issue was discovered in Lantronix EDS5000 2.1.0.0R3. An authenticated attacker can inject OS commands into the "tunnel" parameter when killing a tunnel connection. Injected commands are executed with root privileges.
Vulnerability class: Command Injection (OS Command Injection)
Published · last modified .
CVSS v3 metric
CVSS v3 base score 7.2 (High). Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H.
EPSS exploit prediction
EPSS 0.005, 40.1th percentile (scored ); unchanged over 30 days. About EPSS.
Affected products
- Lantronix Eds5000 Series
- Lantronix Eds5008 Firmware — versions 2.1.0.0
- Lantronix Eds5016 Firmware — versions 2.1.0.0
- Lantronix Eds5032 Firmware — versions 2.1.0.0
- Lantronix G520 Series
- Lantronix X300 Series
Weakness classification (CWE)
References
- lantronix.com (Product)
- eds5000.com (Not Applicable)
- www.cisa.gov/news-events/ics-advisories/icsa-26-069-02 (US Government Resource, Third Party Advisory)
- github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-069-02.js…
- www.lantronix.com/technical-support/security-updates/vulnerability-disclosure-p…