Vulnerability in Eg4 Electronics 12000xp
CVE-2025-52586
The MOD3 command traffic between the monitoring application and the inverter is transmitted in plaintext without encryption or obfuscation. This vulnerability may allow an attacker with access to a local network to intercept, manipulate, replay, or forge critical data, including read/write operations for voltage, current, and power configuration, operational status, alarms, telemetry, system reset, or inverter control commands, potentially disrupting power generation or reconfiguring inverter settings.
EPSS: 0.001 (0.2th percentile) — read the EPSS interpretation.
CVSS v3 metric
CVSS v3 base score 6.9 (Medium). Vector: CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:L.
Affected products
- Eg4 Electronics 12000xp — versions all versions
- Eg4 Electronics 12kpv — versions all versions
- Eg4 Electronics 18kpv — versions all versions
- Eg4 Electronics 6000xp — versions all versions
- Eg4 Electronics Flex 18 — versions all versions
- Eg4 Electronics Flex 21 — versions all versions
- Eg4 Electronics Gridboss — versions all versions
Weakness classification (CWE)
Public proof-of-concept exploits
References
Frequently asked questions
- What is CVE-2025-52586?
- CVE-2025-52586 is a medium-severity vulnerability in Eg4 Electronics 12000xp, classified under Cleartext Transmission of Sensitive Information. CVSS score: 6.9/10. Published 2025-08-08.
- How severe is CVE-2025-52586?
- Medium severity. CVSS v3 base score is 6.9 out of 10.
- Is CVE-2025-52586 known to be exploited?
- 1 public proof-of-concept repositories are indexed. Not currently listed in the CISA KEV catalog.