CVE Explore

Vulnerability in Mitsubishi Electric Corporation Pv-Dr004j

CVE-2025-5022

CVSS v3
6.5 Medium
Public exploits
None known
EPSS
0.006 · 50.7th percentile
Published
2025-07-10

Weak Password Requirements vulnerability in Mitsubishi Electric Corporation photovoltaic system monitor “EcoGuideTAB” PV-DR004J all versions and PV-DR004JA all versions allows an attacker within the Wi-Fi communication range between the units of the product (measurement unit and display unit) to derive the password from the SSID. In addition, if the product is configured to enable the individual air conditioner control function, an attacker who has access to the Wi-Fi communication between the units by exploiting this vulnerability may be able to execute ECHONET Lite commands to perform operations such as turning the air conditioner on or off and changing the set temperature. The individual air conditioner control function is available only in display unit version 02.00.01 or later and measurement unit version 02.03.01 or later. The affected products discontinued in 2015, support ended in 2020.

Published · last modified .

CVSS v3 metric

CVSS v3 base score 6.5 (Medium). Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N.

Attack Vector
Adjacent AV:A
Attack Complexity
Low AC:L
Privileges Required
None PR:N
User Interaction
None UI:N
Scope
Unchanged S:U
Confidentiality
High C:H
Integrity
None I:N
Availability
None A:N

EPSS exploit prediction

EPSS 0.006, 50.7th percentile (last changed ); unchanged over 30 days. About EPSS.

Affected products

Weakness classification (CWE)

References