Vulnerability in Siemens Sinema Remote Connect Server
CVE-2025-40818
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP4). Affected applications contain private SSL/TLS keys on the server that are not properly protected allowing any user with server access to read these keys. This could allow an authenticated attacker to impersonate the server potentially enabling man-in-the-middle, traffic decryption or unauthorized access to services that trust these certificates.
Published · last modified .
CVSS v3 metric
CVSS v3 base score 3.3 (Low). Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N.
EPSS exploit prediction
EPSS 0.001, 1.3th percentile (last changed ); unchanged over 30 days. About EPSS.
Affected products
- Siemens Sinema Remote Connect Server — versions 0
- Siemens Sinema Remote Connect Server — versions 3.2
Weakness classification (CWE)
References
- cert-portal.siemens.com/productcert/html/ssa-626856.html (Vendor Advisory)