Vulnerability in Siemens Ruggedcom Rst2428p
CVE-2025-40569
A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions < V3.2), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions < V3.2), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions < V3.2), SCALANCE XCM332 (6GK5332-0GA01-2AC2) (All versions < V3.2), SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) (All versions < V3.2). The "Load Configuration from Local PC" functionality in the web interface of affected products contains a race condition vulnerability. This could allow an authenticated remote attacker to make the affected product load an attacker controlled configuration instead of the legitimate one. Successful exploitation requires that a legitimate administrator invokes the functionality and the attacker wins the race condition.
Vulnerability class: Race Condition
EPSS: 0.003 (17.4th percentile) — read the EPSS interpretation.
CVSS v3 metric
CVSS v3 base score 4.8 (Medium). Vector: CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:N.
Affected products
- Siemens Ruggedcom Rst2428p — versions 0
- Siemens Scalance Xch328 — versions 0
- Siemens Scalance Xcm324 — versions 0
- Siemens Scalance Xcm328 — versions 0
- Siemens Scalance Xcm332 — versions 0
- Siemens Scalance Xrh334 (24 V Dc, 8xfo, Cc) — versions 0
- Siemens Scalance Xrm334 (230 V Ac, 12xfo) — versions 0
- Siemens Scalance Xrm334 (230v Ac, 2x10g, 24xsfp, 8xsfp+) — versions 0
- Siemens Scalance Xrm334 (230 V Ac, 8xfo) — versions 0
- Siemens Scalance Xrm334 (24 V Dc, 12xfo) — versions 0
Weakness classification (CWE)
References
Frequently asked questions
- What is CVE-2025-40569?
- CVE-2025-40569 is a medium-severity vulnerability in Siemens Ruggedcom Rst2428p, classified under Concurrent Execution using Shared Resource with Improper Synchronization (Race Condition). CVSS score: 4.8/10. Published 2025-06-10.
- How severe is CVE-2025-40569?
- Medium severity. CVSS v3 base score is 4.8 out of 10.