Buffer overflow in Tenda Ac7
CVE-2025-11527
- CVSS v3
- 8.8 High
- Public exploits
- None known
- EPSS
- 0.008 · 57.7th percentile
- Published
- 2025-10-09
A vulnerability was determined in Tenda AC7 15.03.06.44. The impacted element is an unknown function of the file /goform/fast_setting_pppoe_set. Executing a manipulation of the argument Password can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized.
Vulnerability class: Buffer Overflow
Published · last modified .
CVSS v3 metric
CVSS v3 base score 8.8 (High). Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H.
EPSS exploit prediction
EPSS 0.008, 57.7th percentile (last changed ); unchanged over 30 days. About EPSS.
Affected products
- Tenda Ac7 — versions 1.0, 15.03.06.44
- Tenda Ac7 Firmware — versions 15.03.06.44
Weakness classification (CWE)
References
- VDB-327665 | Tenda AC7 fast_setting_pppoe_set stack-based overflow (technical-description, Third Party Advisory, VDB Entry, vdb-entry)
- VDB-327665 | CTI Indicators (IOB, IOC, IOA) (signature, Permissions Required, permissions-required, VDB Entry)
- Submit #669856 | Tenda AC7 V15.03.06.44 Buffer Overflow (Third Party Advisory, VDB Entry, third-party-advisory)
- github.com/noahze01/IoT-vulnerable/blob/main/Tenda/AC7/fast_setting_pppoe_set.md (Exploit, Third Party Advisory, exploit)
- www.tenda.com.cn/ (Product, product)