RCE in Siemens Intermesh 7177 Hybrid 2.0 Subscriber
CVE-2024-47901
- CVSS v3
- 10.0 Critical
- Public exploits
- None known
- EPSS
- 0.012 · 69.6th percentile
- Published
- 2024-10-23
A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The web server of affected devices does not sanitize the input parameters in specific GET requests that allow for code execution on operating system level. In combination with other vulnerabilities (CVE-2024-47902, CVE-2024-47903, CVE-2024-47904) this could allow an unauthenticated remote attacker to execute arbitrary code with root privileges.
Vulnerability class: Command Injection (OS Command Injection)
Published · last modified .
CVSS v3 metric
CVSS v3 base score 10.0 (Critical). Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H.
- Attack Vector
- Network
AV:N - Attack Complexity
- Low
AC:L - Privileges Required
- None
PR:N - User Interaction
- None
UI:N - Scope
- Changed
S:C - Confidentiality
- High
C:H - Integrity
- High
I:H - Availability
- High
A:H
EPSS exploit prediction
EPSS 0.012, 69.6th percentile (last changed ); unchanged over 30 days. About EPSS.
Affected products
Weakness classification (CWE)
Public exploits and proof-of-concept code
Also mentioned in 1 other repository (fkie-cad/nvd-json-data-feeds). These reference the CVE in a list, notes or a scanner and are not exploit code for it.
References
- cert-portal.siemens.com/productcert/html/ssa-333468.html (Vendor Advisory)