RCE in Siemens Sinec Security Monitor
CVE-2024-47562
A vulnerability has been identified in SINEC Security Monitor (All versions < V4.9.0). The affected application does not properly neutralize special elements in user input to the ```ssmctl-client``` command.
This could allow an authenticated, lowly privileged local attacker to execute privileged commands in the underlying OS.
Vulnerability class: Command Injection (OS Command Injection)
Published · last modified .
CVSS v3 metric
CVSS v3 base score 8.8 (High). Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H.
EPSS exploit prediction
EPSS 0.003, 18.6th percentile (scored ); unchanged over 30 days. About EPSS.
Affected products
Weakness classification (CWE)
References
- cert-portal.siemens.com/productcert/html/ssa-430425.html (Third Party Advisory)