Out-of-bounds Read in Siemens Teamcenter Visualization V14.2
CVE-2024-45465
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
Vulnerability class: Buffer Overflow
EPSS: 0.002 (15.8th percentile) — read the EPSS interpretation.
CVSS v3 metric
CVSS v3 base score 7.8 (High). Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H.
Affected products
- Siemens Teamcenter Visualization V14.2 — versions 0
- Siemens Teamcenter Visualization V14.3 — versions 0
- Siemens Teamcenter Visualization V2312 — versions 0
- Siemens Tecnomatix_plant_simulation
- Siemens Tecnomatix Plant Simulation V2302 — versions 0
- Siemens Tecnomatix Plant Simulation V2404 — versions 0
Weakness classification (CWE)
Public proof-of-concept exploits
References
- productcert@siemens.com (Vendor Advisory)
- productcert@siemens.com
Frequently asked questions
- What is CVE-2024-45465?
- CVE-2024-45465 is a high-severity vulnerability in Siemens Teamcenter Visualization V14.2, classified under Out-of-bounds Read. CVSS score: 7.8/10. Published 2024-10-08.
- How severe is CVE-2024-45465?
- High severity. CVSS v3 base score is 7.8 out of 10.
- Is CVE-2024-45465 known to be exploited?
- 1 public proof-of-concept repositories are indexed. Not currently listed in the CISA KEV catalog.