Vulnerability in Mitsubishi Electric Corporation Melipc Series Mi5122-Vw
CVE-2024-3904
- CVSS v3
- 8.8 High
- Public exploits
- None known
- EPSS
- 0.002 · 5.8th percentile
- Published
- 2024-07-04
Incorrect Default Permissions vulnerability in Smart Device Communication Gateway preinstalled on MELIPC Series MI5122-VW firmware versions "05" to "07" allows a local attacker to execute arbitrary code by saving a malicious file to a specific folder. As a result, the attacker may disclose, tamper with, destroy or delete information in the product, or cause a denial-of-service (DoS) condition on the product.
Published · last modified .
CVSS v3 metric
CVSS v3 base score 8.8 (High). Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H.
- Attack Vector
- Local
AV:L - Attack Complexity
- Low
AC:L - Privileges Required
- Low
PR:L - User Interaction
- None
UI:N - Scope
- Changed
S:C - Confidentiality
- High
C:H - Integrity
- High
I:H - Availability
- High
A:H
EPSS exploit prediction
EPSS 0.002, 5.8th percentile (last changed ); unchanged over 30 days. About EPSS.
Affected products
- Mitsubishi Electric Corporation Melipc Series Mi5122-Vw — versions Firmware versions "05" to "07"
Weakness classification (CWE)
References
- www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2024-003_en.pdf (vendor-advisory)
- jvn.jp/vu/JVNVU91215350/index.html (government-resource)
- www.cisa.gov/news-events/ics-advisories/icsa-24-191-02 (government-resource)