Path Traversal in Siemens Omnivise T3000 Application Server
CVE-2024-38878
A vulnerability has been identified in Omnivise T3000 Application Server R9.2 (All versions), Omnivise T3000 R8.2 SP3 (All versions), Omnivise T3000 R8.2 SP4 (All versions). Affected devices allow authenticated users to export diagnostics data. The corresponding API endpoint is susceptible to path traversal and could allow an authenticated attacker to download arbitrary files from the file system.
Vulnerability class: Path Traversal (Directory Traversal)
EPSS: 0.115 (95.6th percentile) — read the EPSS interpretation.
CVSS v3 metric
CVSS v3 base score 7.2 (High). Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H.
Affected products
- Siemens Omnivise_t3000_application_server — versions r9.2
- Siemens Omnivise T3000 Application Server R9.2 — versions 0
- Siemens Omnivise T3000 R8.2 Sp3 — versions 0
- Siemens Omnivise T3000 R8.2 Sp4 — versions 0
Weakness classification (CWE)
Public proof-of-concept exploits
References
- productcert@siemens.com (Mitigation, Vendor Advisory)
- af854a3a-2127-422b-91ae-364da2661108
Frequently asked questions
- What is CVE-2024-38878?
- CVE-2024-38878 is a high-severity vulnerability in Siemens Omnivise T3000 Application Server, classified under Path Traversal. CVSS score: 7.2/10. Published 2024-08-02.
- How severe is CVE-2024-38878?
- High severity. CVSS v3 base score is 7.2 out of 10.
- Is CVE-2024-38878 known to be exploited?
- 1 public proof-of-concept repositories are indexed. Not currently listed in the CISA KEV catalog.