Vulnerability in Siemens Simatic Reader Rf610r Cmiit

CVE-2024-37992

A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions < V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versi…

EPSS: 0.004 (32.8th percentile) — read the EPSS interpretation.

CVSS v3 metric

CVSS v3 base score 4.9 (Medium). Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H.

Affected products

Weakness classification (CWE)

Public proof-of-concept exploits

References

Frequently asked questions

What is CVE-2024-37992?
CVE-2024-37992 is a medium-severity vulnerability in Siemens Simatic Reader Rf610r Cmiit, classified under CWE-703. CVSS score: 4.9/10. Published 2024-09-10.
How severe is CVE-2024-37992?
Medium severity. CVSS v3 base score is 4.9 out of 10.
Is CVE-2024-37992 known to be exploited?
1 public proof-of-concept repositories are indexed. Not currently listed in the CISA KEV catalog.