Resource exhaustion in Siemens Simatic Rtls Locating Manager

CVE-2024-33495

A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). The affected application does not properly limit the size of specific logs. This could allow an unauthenticated remote attacker to exhaust system resources by creating a great number of log entries which could potentially lead to a denial of service condition. A successful exploitation requires the attacker to have access to specific SIMATIC RTLS Locating Manager Clients in the deployment.

EPSS: 0.006 (46.9th percentile) — read the EPSS interpretation.

CVSS v3 metric

CVSS v3 base score 6.5 (Medium). Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H.

Affected products

Weakness classification (CWE)

References

Frequently asked questions

What is CVE-2024-33495?
CVE-2024-33495 is a medium-severity vulnerability in Siemens Simatic Rtls Locating Manager, classified under Allocation of Resources Without Limits or Throttling. CVSS score: 6.5/10. Published 2024-05-14.
How severe is CVE-2024-33495?
Medium severity. CVSS v3 base score is 6.5 out of 10.