Out-of-bounds Read in Siemens Jt2go
CVE-2024-26275
A vulnerability has been identified in JT2Go (All versions < V2312.0004), Parasolid V35.1 (All versions < V35.1.254), Parasolid V36.0 (All versions < V36.0.207), Parasolid V36.1 (All versions < V36.1.147), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
Vulnerability class: Buffer Overflow
Published · last modified .
CVSS v3 metric
CVSS v3 base score 7.8 (High). Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H.
EPSS exploit prediction
EPSS 0.002, 9.3th percentile (scored ); unchanged over 30 days. About EPSS.
Affected products
- Siemens Jt2go — versions 0
- Siemens Parasolid
- Siemens Parasolid V35.1 — versions 0
- Siemens Parasolid V36.0 — versions 0
- Siemens Parasolid V36.1 — versions 0
- Siemens Teamcenter Visualization
- Siemens Teamcenter Visualization V14.2 — versions 0
- Siemens Teamcenter Visualization V14.3 — versions 0
- Siemens Teamcenter Visualization V2312 — versions 0
Weakness classification (CWE)
Public exploits and proof-of-concept code
Also mentioned in 1 other repository (JsHuang/CVE-Assigned). These reference the CVE in a list, notes or a scanner and are not exploit code for it.
References
- cert-portal.siemens.com/productcert/html/ssa-222019.html (Vendor Advisory)
- cert-portal.siemens.com/productcert/html/ssa-771940.html (Vendor Advisory)