RCE in Sick Ag Inspectorp61x
CVE-2024-10771
Due to missing input validation during one step of the firmware update process, the product
is vulnerable to remote code execution. With network access and the user level ”Service”, an attacker
can execute arbitrary system commands in the root user’s contexts.
Vulnerability class: RCE (Remote Code Execution)
Published · last modified .
CVSS v3 metric
CVSS v3 base score 8.8 (High). Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H.
EPSS exploit prediction
EPSS 0.011, 66.3th percentile (last changed ); unchanged over 30 days. About EPSS.
Affected products
- Sick Ag Inspectorp61x — versions 0
- Sick Ag Inspectorp62x — versions 0
- Sick Ag Tdc-X401gl — versions all versions
- Sick Ag Tim3xx — versions 0
Weakness classification (CWE)
References
- sick.com/psirt (x_SICK PSIRT Website)
- cdn.sick.com/media/docs/1/11/411/Special_information_CYBERSECURITY_BY_SICK_en_I… (x_SICK Operating Guidelines)
- www.cisa.gov/resources-tools/resources/ics-recommended-practices (x_ICS-CERT recommended practices on Industrial Security)
- www.first.org/cvss/calculator/3.1 (x_CVSS v3.1 Calculator)
- www.sick.com/.well-known/csaf/white/2024/sca-2024-0006.pdf (vendor-advisory)
- www.sick.com/.well-known/csaf/white/2024/sca-2024-0006.json (vendor-advisory, x_csaf)