Path Traversal in Ininet Solutions Spidercontrol Scada Pc Hmi Editor
CVE-2024-10313
iniNet Solutions SpiderControl SCADA PC HMI Editor has a path traversal vulnerability. When the software loads a malicious ‘ems' project template file constructed by an attacker, it can write files to arbitrary directories. This can lead to overwriting system files, causing system paralysis, or writing to startup items, resulting in remote control.
Vulnerability class: Path Traversal (Directory Traversal)
EPSS: 0.005 (39.0th percentile) — read the EPSS interpretation.
CVSS v3 metric
CVSS v3 base score 8.0 (High). Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H.
Affected products
- Ininet Solutions Spidercontrol Scada Pc Hmi Editor — versions 8.10.00.00
Weakness classification (CWE)
References
Frequently asked questions
- What is CVE-2024-10313?
- CVE-2024-10313 is a high-severity vulnerability in Ininet Solutions Spidercontrol Scada Pc Hmi Editor, classified under Path Traversal. CVSS score: 8.0/10. Published 2024-10-24.
- How severe is CVE-2024-10313?
- High severity. CVSS v3 base score is 8.0 out of 10.