Vulnerability in Siemens Simatic Cn 4100

CVE-2023-49621

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). The "intermediate installation" system state of the affected application uses default credential with admin privileges. An attacker could use the credentials to gain complete control of the affected device.

Published · last modified .

CVSS v3 metric

CVSS v3 base score 9.8 (Critical). Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.

EPSS exploit prediction

EPSS: 0.006 (47.6th percentile), scored .

Very low probability of exploitation in the next 30 days; routine patching cadence is appropriate. 48th percentile — 47.6% of CVEs in the catalogue have a lower EPSS than this one. How to read EPSS.

EPSS trend (30 days)EPSS over the last 30 days for CVE-2023-49621: held from 0.006 to 0.006.

EPSS over last 30 days · oldest: 0.006 · newest: 0.006 · change: 0.000

Affected products

Weakness classification (CWE)

References

Frequently asked questions

What is CVE-2023-49621?
CVE-2023-49621 is a critical-severity vulnerability in Siemens Simatic Cn 4100, classified under CWE-1392. CVSS score: 9.8/10. Published 2024-01-09.
How severe is CVE-2023-49621?
Critical severity. CVSS v3 base score is 9.8 out of 10.