Vulnerability in Siemens Cp-8031 Master Module
CVE-2023-42797
A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05.20), CP-8050 MASTER MODULE (All versions < CPCI85 V05.20). The network configuration service of affected devices contains a flaw in the conversion of ipv4 addresses that could lead to an uninitialized variable being used in succeeding validation steps. By uploading specially crafted network configuration, an authenticated remote attacker could be able to inject commands that are executed on the device with root privileges during device startup.
Published · last modified .
CVSS v3 metric
CVSS v3 base score 6.6 (Medium). Vector: CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H.
EPSS exploit prediction
EPSS: 0.005 (43.7th percentile), scored .
Very low probability of exploitation in the next 30 days; routine patching cadence is appropriate. 44th percentile — 43.7% of CVEs in the catalogue have a lower EPSS than this one. How to read EPSS.
EPSS over last 30 days · oldest: 0.005 · newest: 0.005 · change: 0.000
Affected products
- Siemens Cp-8031 Master Module — versions All versions < CPCI85 V05.20
- Siemens Cp-8050 Master Module — versions All versions < CPCI85 V05.20
- Siemens Sicam A8000 Cp-8031
- Siemens Sicam A8000 Cp-8031 Firmware
- Siemens Sicam A8000 Cp-8050
- Siemens Sicam A8000 Cp-8050 Firmware
Weakness classification (CWE)
References
- cert-portal.siemens.com/productcert/pdf/ssa-583634.pdf (Patch, Vendor Advisory)
Frequently asked questions
- What is CVE-2023-42797?
- CVE-2023-42797 is a medium-severity vulnerability in Siemens Cp-8031 Master Module, classified under Use of Uninitialized Resource. CVSS score: 6.6/10. Published 2024-01-09.
- How severe is CVE-2023-42797?
- Medium severity. CVSS v3 base score is 6.6 out of 10.