Auth bypass in Boschrexroth Ctrlx Hmi Web Panel Wr2107 Firmware
CVE-2023-41255
The vulnerability allows an unprivileged user with access to the subnet of the TPC-110W device to gain a root shell on the device itself abusing the lack of authentication
of the ‘su’ binary file installed on the device that can be accessed through the ADB (Android Debug Bridge) protocol exposed on the network.
Vulnerability class: Broken Authentication
Published · last modified .
CVSS v3 metric
CVSS v3 base score 8.8 (High). Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.
EPSS exploit prediction
EPSS 0.005, 42.9th percentile (scored ); unchanged over 30 days. About EPSS.
Affected products
- Boschrexroth Ctrlx Hmi Web Panel Wr2107 Firmware
- Boschrexroth Ctrlx Hmi Web Panel Wr2110 Firmware
- Boschrexroth Ctrlx Hmi Web Panel Wr2115 Firmware
- Rexroth Ctrlx Hmi Web Panel - Wr21 (Wr2107) — versions all
- Rexroth Ctrlx Hmi Web Panel - Wr21 (Wr2110) — versions all
- Rexroth Ctrlx Hmi Web Panel - Wr21 (Wr2115) — versions all
Weakness classification (CWE)
References
- https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html (vendor-advisory, Mitigation, Vendor Advisory)