Buffer overflow in Siemens Parasolid
CVE-2023-41032
- CVSS v3
- 7.8 High
- Public exploits
- None known
- EPSS
- 0.002 · 15.8th percentile
- Published
- 2023-09-12
A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.253), Parasolid V35.1 (All versions < V35.1.184), Parasolid V36.0 (All versions < V36.0.142), Simcenter Femap V2301 (All versions < V2301.0003), Simcenter Femap V2306 (All versions < V2306.0001). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21263)
Vulnerability class: Buffer Overflow
Published · last modified .
CVSS v3 metric
CVSS v3 base score 7.8 (High). Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H.
- Attack Vector
- Local
AV:L - Attack Complexity
- Low
AC:L - Privileges Required
- None
PR:N - User Interaction
- Required
UI:R - Scope
- Unchanged
S:U - Confidentiality
- High
C:H - Integrity
- High
I:H - Availability
- High
A:H
EPSS exploit prediction
EPSS 0.002, 15.8th percentile (last changed ); unchanged over 30 days. About EPSS.
Affected products
- Siemens Parasolid
- Siemens Parasolid V34.1 — versions All versions < V34.1.258
- Siemens Parasolid V35.0 — versions All versions < V35.0.253
- Siemens Parasolid V35.1 — versions All versions < V35.1.184
- Siemens Parasolid V36.0 — versions All versions < V36.0.142
- Siemens Simcenter Femap
- Siemens Simcenter Femap V2301 — versions All versions < V2301.0003
- Siemens Simcenter Femap V2306 — versions All versions < V2306.0001
Weakness classification (CWE)
References
- cert-portal.siemens.com/productcert/pdf/ssa-190839.pdf (Vendor Advisory)
- cert-portal.siemens.com/productcert/pdf/ssa-887122.pdf (Vendor Advisory)
- www.bentley.com/advisories/be-2023-0004/ (Third Party Advisory)