Out-of-bounds Read in Siemens Parasolid
CVE-2023-38530
- CVSS v3
- 7.8 High
- Public exploits
- None known
- EPSS
- 0.002 · 11.3th percentile
- Published
- 2023-08-08
A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.171), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
Vulnerability class: Buffer Overflow
Published · last modified .
CVSS v3 metric
CVSS v3 base score 7.8 (High). Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H.
- Attack Vector
- Local
AV:L - Attack Complexity
- Low
AC:L - Privileges Required
- None
PR:N - User Interaction
- Required
UI:R - Scope
- Unchanged
S:U - Confidentiality
- High
C:H - Integrity
- High
I:H - Availability
- High
A:H
EPSS exploit prediction
EPSS 0.002, 11.3th percentile (last changed ); unchanged over 30 days. About EPSS.
Affected products
- Siemens Parasolid
- Siemens Parasolid V34.1 — versions 0
- Siemens Parasolid V35.0 — versions 0
- Siemens Parasolid V35.1 — versions 0
- Siemens Teamcenter Visualization
- Siemens Teamcenter Visualization V14.1 — versions 0
- Siemens Teamcenter Visualization V14.2 — versions 0
- Siemens Teamcenter Visualization V14.3 — versions 0