RCE in Siemens 6gk1411-1ac00
CVE-2023-28832
A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1). The web based management of affected devices does not properly validate user input, making it susceptible to command injection. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.
Vulnerability class: Command Injection (OS Command Injection)
EPSS: 0.015 (73.1th percentile) — read the EPSS interpretation.
CVSS v3 metric
CVSS v3 base score 7.2 (High). Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H.
Affected products
- Siemens 6gk1411-1ac00
- Siemens 6gk1411-1ac00_firmware — versions 2.0
- Siemens 6gk1411-5ac00
- Siemens 6gk1411-5ac00_firmware — versions 2.0
- Siemens Simatic Cloud Connect 7 Cc712 — versions All versions >= V2.0 < V2.1
- Siemens Simatic Cloud Connect 7 Cc716 — versions All versions >= V2.0 < V2.1
Weakness classification (CWE)
References
- productcert@siemens.com (Patch, Vendor Advisory)
Frequently asked questions
- What is CVE-2023-28832?
- CVE-2023-28832 is a high-severity vulnerability in Siemens 6gk1411-1ac00, classified under Command Injection. CVSS score: 7.2/10. Published 2023-05-09.
- How severe is CVE-2023-28832?
- High severity. CVSS v3 base score is 7.2 out of 10.