Information disclosure in Miniflux V2
CVE-2023-27591
Miniflux is a feed reader. Prior to version 2.0.43, an unauthenticated user can retrieve Prometheus metrics from a publicly reachable Miniflux instance where the `METRICS_COLLECTOR` configuration option is enabled and `METRICS_ALLOWED_NETWORKS` is set to `127.0.0.1/8` (the default). A patch is available in Miniflux 2.0.43. As a workaround, set `METRICS_COLLECTOR` to `false` (default) or run Miniflux behind a trusted reverse-proxy.
Vulnerability class: Information Disclosure
Published · last modified .
CVSS v3 metric
CVSS v3 base score 7.5 (High). Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N.
EPSS exploit prediction
EPSS 0.008, 55.7th percentile (last changed ); unchanged over 30 days. About EPSS.
Affected products
- Miniflux V2 — versions < 2.0.43
- Miniflux Project
Weakness classification (CWE)
Public exploits and proof-of-concept code
Also mentioned in 2 other repositories (40826d/advisories, ARPSyndicate/cvemon). These reference the CVE in a list, notes or a scanner and are not exploit code for it.
References
- https://github.com/miniflux/v2/security/advisories/GHSA-3qjf-qh38-x73v (Vendor Advisory)
- https://github.com/miniflux/v2/pull/1745 (Patch, Issue Tracking)
- https://github.com/miniflux/v2/releases/tag/2.0.43 (Release Notes)
- https://miniflux.app/docs/configuration.html#metrics-collector (Product)