Path Traversal in Siemens Sinec Ins
CVE-2022-45092
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 1). An authenticated remote attacker with access to the Web Based Management (443/tcp) of the affected product, could potentially read and write arbitrary files from and to the device's file system. An attacker might leverage this to trigger remote code execution on the affected component.
Vulnerability class: Path Traversal (Directory Traversal)
Published · last modified .
CVSS v3 metric
CVSS v3 base score 9.9 (Critical). Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H.
EPSS exploit prediction
EPSS: 0.314 (98.3th percentile), scored .
Moderate probability of exploitation in the next 30 days — watch for active exploitation reports. 98th percentile — 98.3% of CVEs in the catalogue have a lower EPSS than this one. How to read EPSS.
EPSS over last 30 days · oldest: 0.314 · newest: 0.314 · change: 0.000
Affected products
- Siemens Sinec Ins — versions All versions < V1.0 SP2 Update 1
- Siemens Sinec Ins — versions 1.0
Weakness classification (CWE)
Public proof-of-concept exploits
References
- cert-portal.siemens.com/productcert/pdf/ssa-332410.pdf (Vendor Advisory)
Frequently asked questions
- What is CVE-2022-45092?
- CVE-2022-45092 is a critical-severity vulnerability in Siemens Sinec Ins, classified under Path Traversal. CVSS score: 9.9/10. Published 2023-01-10.
- How severe is CVE-2022-45092?
- Critical severity. CVSS v3 base score is 9.9 out of 10.
- Is CVE-2022-45092 known to be exploited?
- 1 public proof-of-concept repositories are indexed. Not currently listed in the CISA KEV catalog.