Vulnerability in Sinilink Xy-Wft1

CVE-2022-43704

The Sinilink XY-WFT1 WiFi Remote Thermostat, running firmware 1.3.6, allows an attacker to bypass the intended requirement to communicate using MQTT. It is possible to replay Sinilink aka SINILINK521 protocol (udp/1024) commands interfacing directly with the target device. This, in turn, allows for an attack to control the onboard relay without requiring authentication via the mobile application. This might result in an unacceptable temperature within the target device's physical environment.

EPSS: 0.019 (77.2th percentile) — read the EPSS interpretation.

CVSS v3 metric

CVSS v3 base score 5.9 (Medium). Vector: CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N.

Affected products

Weakness classification (CWE)

Public proof-of-concept exploits

References

Frequently asked questions

What is CVE-2022-43704?
CVE-2022-43704 is a medium-severity vulnerability in Sinilink Xy-Wft1, classified under Authentication Bypass by Capture-replay. CVSS score: 5.9/10. Published 2023-01-20.
How severe is CVE-2022-43704?
Medium severity. CVSS v3 base score is 5.9 out of 10.
Is CVE-2022-43704 known to be exploited?
10 public proof-of-concept repositories are indexed. Not currently listed in the CISA KEV catalog.