Improper input validation in Siemens 7kg9501-0aa01-2aa1

CVE-2022-43439

A vulnerability has been identified in POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) (All versions < V2.50), POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) (All versions < V2.50), POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) (All versions < V2.50), POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) (All versions < V2.50), SICAM P850 (7KG8500-0AA00-0AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA00-2AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA10-0AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA10-2AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA30-0AA0) (All versions < V3.10), SICAM P850 (7KG8500-0AA30-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA01-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA01-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA02-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA02-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA11-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA11-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA12-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA12-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA31-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA31-2AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA32-0AA0) (All versions < V3.10), SICAM P850 (7KG8501-0AA32-2AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA00-0AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA00-2AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA10-0AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA10-2AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA30-0AA0) (All versions < V3.10), SICAM P855 (7KG8550-0AA30-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA01-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA01-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA02-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA02-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA11-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA11-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA12-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA12-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA31-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA31-2AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA32-0AA0) (All versions < V3.10), SICAM P855 (7KG8551-0AA32-2AA0) (All versions < V3.10), SICAM T (All versions < V3.0). Affected devices do not properly validate the Language-parameter in requests to the web interface on port 443/tcp. This could allow an authenticated remote attacker to crash the device (followed by an automatic reboot) or to execute arbitrary code on the device.

Vulnerability class: Drupalgeddon 2 (CVE-2018-7600)

EPSS: 0.015 (71.4th percentile) — read the EPSS interpretation.

CVSS v3 metric

CVSS v3 base score 9.9 (Critical). Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H.

Affected products

Weakness classification (CWE)

References

Frequently asked questions

What is CVE-2022-43439?
CVE-2022-43439 is a critical-severity vulnerability in Siemens 7kg9501-0aa01-2aa1, classified under Improper Input Validation. CVSS score: 9.9/10. Published 2022-11-08.
How severe is CVE-2022-43439?
Critical severity. CVSS v3 base score is 9.9 out of 10.