CVE Explore

Path Traversal in Schneider Electric Ecostruxure Operator Terminal Expert

CVE-2022-41670

CVSS v3
7.0 High
Public exploits
None known
EPSS
0.002 · 10.9th percentile
Published
2022-11-04

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in the SGIUtility component that allows adversaries with local user privileges to load malicious DLL which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior).

Vulnerability class: Path Traversal (Directory Traversal)

Published · last modified .

CVSS v3 metric

CVSS v3 base score 7.0 (High). Vector: CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H.

Attack Vector
Local AV:L
Attack Complexity
High AC:H
Privileges Required
Low PR:L
User Interaction
None UI:N
Scope
Unchanged S:U
Confidentiality
High C:H
Integrity
High I:H
Availability
High A:H

EPSS exploit prediction

EPSS 0.002, 10.9th percentile (last changed ); unchanged over 30 days. About EPSS.

Affected products

Weakness classification (CWE)

References