Path Traversal in Schneider Electric Ecostruxure Operator Terminal Expert
CVE-2022-41667
- CVSS v3
- 7.0 High
- Public exploits
- None known
- EPSS
- 0.002 · 15.1th percentile
- Published
- 2022-11-04
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that allows adversaries with local user privileges to load a malicious DLL which could lead to execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior).
Vulnerability class: Path Traversal (Directory Traversal)
Published · last modified .
CVSS v3 metric
CVSS v3 base score 7.0 (High). Vector: CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H.
- Attack Vector
- Local
AV:L - Attack Complexity
- High
AC:H - Privileges Required
- Low
PR:L - User Interaction
- None
UI:N - Scope
- Unchanged
S:U - Confidentiality
- High
C:H - Integrity
- High
I:H - Availability
- High
A:H
EPSS exploit prediction
EPSS 0.002, 15.1th percentile (last changed ); unchanged over 30 days. About EPSS.
Affected products
- Schneider Electric Ecostruxure Operator Terminal Expert — versions V3.3
- Schneider Electric Pro-Face Blue — versions V3.3
- Schneider-Electric Ecostruxure Operator Terminal Expert — versions 3.3
- Schneider-Electric Pro-Face Blue — versions 3.3
Weakness classification (CWE)
References
- www.se.com/ww/en/download/document/SEVD-2022-284-01/ (Patch, Vendor Advisory)