Auth bypass in Delta Electronics Infrasuite Device Master
CVE-2022-41629
- CVSS v3
- 7.5 High
- Public exploits
- None known
- EPSS
- 0.007 · 55.2th percentile
- Published
- 2022-10-31
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing administrative passwords.
Vulnerability class: Broken Authentication
Published · last modified .
CVSS v3 metric
CVSS v3 base score 7.5 (High). Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N.
EPSS exploit prediction
EPSS 0.007, 55.2th percentile (last changed ); unchanged over 30 days. About EPSS.
Affected products
Weakness classification (CWE)
References
- www.cisa.gov/uscert/ics/advisories/icsa-22-298-07 (US Government Resource, Patch, Third Party Advisory, government-resource)