Auth bypass in Delta Electronics Infrasuite Device Master

CVE-2022-40202

The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication. An attacker could provide malicious serialized objects which, when deserialized, could activate an opcode for a backup scheduling function without authentication. This function allows the user to designate all function arguments and the file to be executed. This could allow the attacker to start any new process and achieve remote code execution.

Vulnerability class: Broken Authentication

Published · last modified .

CVSS v3 metric

CVSS v3 base score 9.8 (Critical). Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.

EPSS exploit prediction

EPSS: 0.013 (70.2th percentile), scored .

Low probability of exploitation in the next 30 days, but still tracked. 70th percentile — 70.2% of CVEs in the catalogue have a lower EPSS than this one. How to read EPSS.

EPSS trend (30 days)EPSS over the last 30 days for CVE-2022-40202: held from 0.013 to 0.013.

EPSS over last 30 days · oldest: 0.013 · newest: 0.013 · change: +0.000

Affected products

Weakness classification (CWE)

References

Frequently asked questions

What is CVE-2022-40202?
CVE-2022-40202 is a critical-severity vulnerability in Delta Electronics Infrasuite Device Master, classified under Missing Authentication for Critical Function. CVSS score: 9.8/10. Published 2022-10-31.
How severe is CVE-2022-40202?
Critical severity. CVSS v3 base score is 9.8 out of 10.