Vulnerability in Omron Nj101-1000
CVE-2022-31206
The Omron SYSMAC Nx product family PLCs (NJ series, NY series, NX series, and PMAC series) through 2022-005-18 lack cryptographic authentication. These PLCs are programmed using the SYMAC Studio engineering software (which compiles IEC 61131-3 conformant POU code to native machine code for execution by the PLC's runtime). The resulting machine code is executed by a runtime, typically controlled by a real-time operating system. The logic that is downloaded to the PLC does not seem to be cryptographically authenticated, allowing an attacker to manipulate transmitted object code to the PLC and execute arbitrary machine code on the processor of the PLC's CPU module in the context of the runtime. In the case of at least the NJ series, an RTOS and hardware combination is used that would potentially allow for memory protection and privilege separation and thus limit the impact of code execution. However, it was not confirmed whether these sufficiently segment the runtime from the rest of the RTOS.
EPSS: 0.010 (60.1th percentile) — read the EPSS interpretation.
CVSS v3 metric
CVSS v3 base score 9.8 (Critical). Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H.
Affected products
Weakness classification (CWE)
References
- cve@mitre.org (Third Party Advisory, x_refsource_MISC)
- cve@mitre.org (US Government Resource, Third Party Advisory, x_refsource_MISC)
Frequently asked questions
- What is CVE-2022-31206?
- CVE-2022-31206 is a critical-severity vulnerability in Omron Nj101-1000, classified under Improper Verification of Cryptographic Signature. CVSS score: 9.8/10. Published 2022-07-26.
- How severe is CVE-2022-31206?
- Critical severity. CVSS v3 base score is 9.8 out of 10.